AGA Electricity Supply

Most AGAs require an electricity supply, some just a 13amp socket, others a 32amp 'Cooker Circuit', there's a list of the requirements below however we can provide a more detailed specification after carrying out a home survey.

Fuel / Model 2 Oven 3 Oven 4 Oven 5 Oven

Gas Conventional Flue AGA (excluding Dual Control)

Non-AIMS
No Module
None required when no AIMS and no Module n/a
With AIMS 13amp switched socket n/a
With Module 32amp cooker circuit n/a
AIMS & Module 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket n/a

Gas Powered Flue AGA (excluding Dual Control)

No Module All power flue AGAs (with or without AIMS) require 13amp socket for the flue fan n/a
With AIMS Uses same supply from 13amp socket n/a
With Module 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket n/a
AIMS & Module 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket n/a

Electric Economy 7 AGA (also known as '30amp Electric AGA')

Three oven and AIMS not available 32amp cooker circuit (on all the time)
Plus a 6amp 'signal'/trigger circuit which is on only during 'Economy 7' times
n/a
With Module A second (two in total) 32amp cooker circuit n/a

Electric 13amp AGA

With or without AIMS
No Module

13amp switched fused spur point (2.5kW load)
DO NOT USE PLUG/SOCKET - USE A SWITCHED FUSED SPUR POINT.
Recommended to be on its own 16amp circuit breaker

n/a
With Module An additional 32amp cooker circuit
It is NOT possible to plug the 13amp AGA in to the socket on a combined cooker control with socket
n/a

Electric Total Control AGA

No Module n/a 32amp cooker circuit n/a 32amp cooker circuit
+13amp socket
With Module n/a A second (two in total) 32amp cooker circuit n/a A second (two in total) 32amp cooker circuit
+13amp socket

Dual Control AGA (All-Electric or Gas-Electric)

No Module n/a 32amp cooker circuit n/a 32amp cooker circuit
+13amp socket
With Module n/a A second (two in total) 32amp cooker circuit n/a A second (two in total) 32amp cooker circuit
+13amp socket

AGA 3 Series Cookers (eR3 100-3 and 100-4 Models)

eR3 100-3 and 100-4
(non-induction)
32amp cooker circuit n/a
eR3 100-3i and 100-4i
(with induction)
32amp cooker circuit
and a 13amp socket outlet
n/a

AGA 60 (All-Electric or Dual Fuel Model)

32amp cooker circuit n/a n/a

Oil Fired AGA

No Module 13amp socket n/a 13amp socket outlet n/a
With Module 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket n/a 13amp socket + 32amp cooker circuit - use a cooker outlet with integral socket n/a

2-Zone Ceramic Electric or Gas Hob for Four Oven AGA
Induction Hob for Five oven Dual/Total Control AGA
(Optional, instead of warming plate on warming cupboard)

2-Zone gas or electric ceramic hob (4 oven only) 13amp socket outlet to left of AGA n/a
Induction hob (5 Oven Dual/Total Control only) n/a Nothing extra - fed from existing Warming Cupboard socket

AGA Freestanding Module

Gas or electric ceramic hob version 32amp cooker circuit n/a

AGA Six-Four Cooker

Gas hob version 32amp cooker circuit (6.6kW) n/a
Electric ceramic hob version 45amp cooker circuit which MUST be wired using 10 sq mm cable (16.9kW) n/a

AGA Masterchef XL 110

Dual Fuel (gas hob / electric ovens) 32amp cooker circuit (12kW) n/a
With Induction hob 45amp cooker circuit (17kW) n/a

AGA Masterchef XL 90

Dual Fuel (gas hob / electric ovens) 32amp cooker circuit (8.6kW) n/a
With Induction hob 45amp cooker circuit (16kW) n/a